Ivoclar-vivadent EP 600 Combi Manuale Utente

Navigare online o scaricare Manuale Utente per Apparecchiature Ivoclar-vivadent EP 600 Combi. Ivoclar Vivadent EP 600 Combi User Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa

Sommario

Pagina 1 - EP 600 Combi

Operating InstructionsEP 600 CombiPress Furnace and Ceramic FurnaceValid as of Software Version V4.0

Pagina 2

102.1.4Risk of crushing / burn hazardNever reach under the furnacehead during operation. There isa risk of crushing and a burnhazard.2.1.6Contraindica

Pagina 3 - Table of Contents

112.1.9ContraindicationPress cycles must not beconducted without the firingplate (50) in place.2.1.10Contraindication The firing plate (50) must becorre

Pagina 4 - List of Parts

122.1.15ContraindicationThe furnace head must not becarried by holding the cables, asthere is a risk of damaging thecables and the correspondingconnec

Pagina 5

132.2 Health and safety instructionsThis furnace has been designedaccording to EN 61010-1 andhas been shipped from themanufacturer in safe operatingco

Pagina 6

143. Product Description3.1 ComponentsThe EP600 Combi Press andCeramic Furnace comprises thefollowing components:– Furnace base with electroniccontrol

Pagina 7

154.1 Unpacking and checking the contentsThe new packaging provides thefollowing advantages:– Reusable packaging– Closing mechanism with inte-grated t

Pagina 8 - T5A T12A T2A

16The furnace components areassembled as follows:Step 1:Assembling the tray and thefiring plate– Mount the supports for thesagger tray (25)– The sagger

Pagina 9 - 2. Safety First

17Step 6:Setting-up the cooling grid forinvestment ringsThe cooling grid for investmentrings is supplied fully assembled.Please position the grid in a

Pagina 10

18Step 7:Connecting the card readerConnect the adapter (165) withthe RS232 PC/Printer interface(14) and insert the plug (161) orthe card reader (Type

Pagina 11

195.1 Starting the furnace5.1.1 Start-upAfter the furnace has been switched on, theunit undergoes a self-test, and if necessary, apreheating cycle. Th

Pagina 13 - 2.2 Health and safety

Please use only the originalstandard programs, which areespecially coordinated with thecorresponding materials for theIvoclar Vivadent all-ceramic sys

Pagina 14 - 3. Product Description

21Internal programsWith this menu item, you may access 50 individual firing programs that are stored in the furnace.Program memory cardThis option also

Pagina 15 - 4.3 Assembly and initial

22Important noteVacuum:If the value 0 is entered for V1 and V2, no vacuum will be created.Long-term coolingValues between 50 and 1200 °C (122 and2192

Pagina 16

235.4 Introduction to the menu "Miscellaneous"This menu is called up via the main menu. It permits the selection of a number oflower-level

Pagina 17

24Direct –>Press/Firing programs areprotocolled (Press/ Firing programprotocol table) and are shown or printedimmediately on the serial interfaceRS

Pagina 18

255.5 Operating the menu / key functions5.5.1 Navigation1231 Information lineThis line always shows the most currenttemperature and operating mode. A

Pagina 19 - 5.2 Introduction to the

266.1 Switching on/offPut the I/O switch at the rear of the furnaceon position "I". The furnace is now switchedon and the EP600 logo appears

Pagina 20 - 5.3 Introduction to the

27What Part WhenCheck all plug-in connections for correct fit Various external connections weeklyCheck if the furnace head opens smoothly and without

Pagina 21

287.3 Menu "Access alarm table"In this menu, up to 20 of the last alarmmessages are listed in a table. In case ofinquiries, please provide t

Pagina 22

297.6 Changing the press plungerIn order to facilitate the changing of thepress plunger, we recommend lowering thepress plunger manually by using thec

Pagina 23 - "Miscellaneous"

3Table of ContentsPageViews of the Furnace, List of Parts 41 Introduction / Signs and Symbols 81.1 Preface1.2 Signs and Symbols1.3 Notes regarding the

Pagina 24

30This chapter will help you to recognizemalfunctions and take the appropriatemeasures or, if possible, to perform minorrepairs.8.1 Error messages and

Pagina 25 - Output of protocols

318.2 Technical malfunctionsThese malfunctions may occur without an error message being displayed:Description Double-Check ActionVacuum is not or only

Pagina 26 - 6. Practical Use

32Description Double-Check ActionFinal vacuum is not reached Is the vacuum hose OK? Check vacuum hose (13) and hose connection.Was the absolute value

Pagina 27 - 7.1 Monitoring and

339.2 Technical dataPower supply: 200–240 Volt, 50–60 Hz110–120 Volt, 50–60 HzInstallation category II Max. power consumption: 12 A at 110–120 VAC8,5

Pagina 28 - 7.5 Temperature calibration

349.3 Acceptable operating conditions– Acceptable temperaturerange:+5 °C to +40 °C(+41 °F to +104 °F)– Acceptable humidity rangeMaximum relative humid

Pagina 29 - 7.7 Changing the firing tray

3510. MiscellaneousThe program parameters are set in thefactory. The parameters used may differ,but they are based on the latest standardof technology

Pagina 30 - 8. What If…

3610.2 Firing table4)These values are related to the possible set values. The actually achieved values however may differ and depend on various factor

Pagina 31 - 8.2 Technical malfunctions

Description:F1... skip into the next menu below with F1(F3)... skip back with F33710.3 Menu structure of the EP600 CombiPreheatingStartF2...F3Main men

Pagina 32 - 8.3 Repair

3810.4 1-step firing program

Pagina 33 - 9. Product Specification

3910.5 2-step firing program

Pagina 34 - 9.4 Acceptable

4List of PartsA = Furnace Base 1 Sagger tray BP12 Screws for sagger tray3 Rubber foot4 Air vents5 On/Off switch6 Power socket7 Vacuum pump socket8 Ext

Pagina 35 - 10. Miscellaneous

Ivoclar Vivadent AGBendererstrasse 2FL-9494 SchaanLiechtensteinTel. +423 235 35 35Fax +423 235 33 60www.ivoclarvivadent.comIvoclar Vivadent Pty. Ltd.1

Pagina 36 - 10.2 Firing table

5455441179515473123535452141020127689

Pagina 37 - F3, (F1)

656707172696855151924507480736365646267661141081041021031011001051061071091101111121135857566061628159

Pagina 38 - 10.4 1-step firing program

712552171379115475181617237322121122140123767778DE164163161160170150162165GFH

Pagina 39 - 10.5 2-step firing program

81.1 PrefaceDear Customer,Thank you for having purchasedthe EP600 Combi Press andCeramic Furnace. This furnacewith the intelligent press drivehas been

Pagina 40 - Ivoclar Vivadent – worldwide

2. Safety FirstThis chapter is especially important for individualswho work with the EP600 Combi or who have tocarry out maintenance or repair work. T

Commenti su questo manuale

Nessun commento