Operating InstructionsEP 600Press FurnaceValid as of Software Version V4.0

Pagina 2

102.1.4Risk of crushing / burn hazardNever reach under the furnacehead during operation. There isa risk of crushing and a burnhazard.2.1.6Contraindica

Pagina 3 - Table of Contents

112.1.9ContraindicationPress cycles must not beconducted without the firingplate (50) in place.2.1.10Contraindication The firing plate (50) must becorre

Pagina 4 - List of Parts

122.2 Health and safety instructionsThis furnace has been designedaccording to EN 61010-1 andhas been shipped from themanufacturer in safe operatingco

Pagina 5

133. Product Description3.1 ComponentsThe EP 600 Press Furnacecomprises the followingcomponents:– Furnace base with electroniccontrols– Furnace head w

Pagina 6

144.1 Unpacking and checking the contentsThe new packaging provides thefollowing advantages:– Reusable packaging– Closing mechanism with inte-grated t

Pagina 7

15The furnace components areassembled as follows:Step 1:Assembling the tray and thefiring plate– Mount the supports for thesagger tray (25)– The sagger

Pagina 8 - T5A T12A T2A

The RS232 interface (14) may also be used toconnect a printer or a PC in order to save or printfiring protocols.16Step 6:Setting-up the cooling grid fo

Pagina 9 - 2. Safety First

17Disassembling the furnace headNote: Before the furnace headconnections cover is removed,the furnace should be switchedoff and the power cord (21)unp

Pagina 10

185.1 Starting the furnace5.1.1 Start-upAfter the furnace has been switched on, theunit undergoes a self-test, and if necessary, apreheating cycle. Th

Pagina 11

Please use only the originalstandard programs, which areespecially coordinated with thecorresponding materials for theIvoclar Vivadent all-ceramic sys

Pagina 13 - 3. Product Description

205.3 Introduction to the menu "Miscellaneous"This menu is called up via the main menu. It permits the selection of a number oflower-level

Pagina 14 - 4.3 Assembly and initial

21Direct –> Press/Firing programs areprotocolled (Press/ Firing programprotocol table) and are transmitted orprinted immediately on the serialinter

Pagina 15

225.4 Operating the menu / key functions5.4.1 Navigation1231 Information lineThis line always shows the most currenttemperature and operating mode. Ad

Pagina 16

236.1 Switching on/offPut the I/O switch at the rear of the furnaceon position "I". The furnace is now switchedon and the EP600 logo appears

Pagina 17

24What Part WhenCheck all plug-in connections for correct fit Various external connections weeklyCheck if the furnace head opens smoothly and without

Pagina 18 - 5.2 Introduction to the

257.3 Menu "Access alarm table"In this menu, up to 20 of the last alarmmessages are listed in a table. In case ofinquiries, please provide t

Pagina 19

267.6 Changing the press plungerIn order to facilitate the changing of thepress plunger, we recommend lowering thepress plunger manually by using thec

Pagina 20 - "Miscellaneous"

27This chapter will help you to recognizemalfunctions and take the appropriatemeasures or, if possible, to perform minorrepairs.8.1 Error messages and

Pagina 21

288.2 Technical malfunctionsThese malfunctions may occur without an error message being displayed:Description Double-Check ActionVacuum is not or only

Pagina 22 - 5.6 Protocolling / Output of

29Description Double-Check ActionFinal vacuum is not reached Is the vacuum hose OK? Check vacuum hose (13) and hose connection.Was the absolute value

Pagina 23 - 6. Practical Use

3Table of ContentsPageViews of the Furnace, List of Parts 41 Introduction / Signs and Symbols 81.1 Preface1.2 Signs and Symbols1.3 Notes regarding the

Pagina 24 - 7.1 Monitoring and

309.2 Technical dataPower supply: 200–240 Volt, 50–60 Hz110–120 Volt, 50–60 HzInstallation category II Max. power consumption: 12 A at 110–120 VAC8,5

Pagina 25 - 7.5 Temperature calibration

319.3 Acceptable operating conditions– Acceptable temperaturerange:+5 °C to +40 °C(+41 °F to +104 °F)– Acceptable humidity rangeMaximum relative humid

Pagina 26

3210. Miscellaneous10.1 Press tableThe program parameters are set in thefactory. The parameters used may differ,but they are based on the latest stand

Pagina 27 - 8. What If…

Description:F1... skip into the next menu below with F1(F3)... skip back with F33310.2 Menu structure of the EP 600PreheatingStartF2...F3Main menu &qu

Pagina 30 - 9. Product Specification

Ivoclar Vivadent – worldwideThis apparatus has been developed solely for use indentistry. Start-up and operation should be donestrictly according to t

Pagina 31 - 9.4 Acceptable

4List of PartsA = Furnace Base 1 Sagger tray BP12 Screws for sagger tray3 Rubber foot4 Air vents5 On/Off switch6 Power socket7 Vacuum pump socket8 Ext

Pagina 32 - 10. Miscellaneous

5455441179515473123535452141020127689

Pagina 33 - F3, (F1)

656707172696855151924507480736365646267661141081041021031011001051061071091101111121135857566061628159

Pagina 34

712552171379115475181617237322121122140123767778DE

Pagina 35

81.1 PrefaceDear Customer,Thank you for having purchasedthe EP 600 Press Furnace. Thisfurnace with the intelligent pressdrive has been especiallydevel

Pagina 36 - Ivoclar Vivadent – worldwide

2. Safety FirstThis chapter is especially important for individualswho work with the EP 600 or who have to carryout maintenance or repair work. This c